Spec. of EVT-200V30A EV/HEV/PHEV Battery Testing System

EVTS-200V30A   EV/HEV/PHEV Battery Testing System

 

Equipment Model EVTS-200V30A Battery Testing Equipment        Equipment Item CodeCE-6001W-200V30A
Project index
Parameter index
Input Power
AC 380V ±10% 50Hz/60Hz
resolution
14bit
Single-phase power
3KW
Single-phase current
12A
Input Power
8KW
Voltage
Per Channel Voltage Range
Charge10V~200VDischarge10V~200V
Accuracy
± 0.5% of rangeFull-scale
Stability
± 0.5% of rangeFull-scale
Current
Per Channel Current Range
Charge1.5A~30ADischarge1.5A~30A
Accuracy
± 0.5% of rangeFull-scale
Stability
± 0.5% of rangeFull-scale
Power
Per Channel Output Power
6KW
Stability
± 2% of rangeFull-scale
Time
Current Response Time
The Current gets to 30A Hardware Response Time is 1s
Step Time Range
Single Step Time Range≤365*24 h
Time Form Support 000000(hmins)
Auxiliary Channel
Type of Auxiliary Channel
Test&Control Temperature &Voltage of unit cell (max with 248 auxiliary channels)
Temperature Range
25~110
Temperature Stability
±1% of reading + 1
Temperature Resolution
0.1
Voltage Range
10 mV~5V
Voltage Stability
± 0.1% of full range
Data Recording
Record Condition
Time△t:(1s ~60000s
Voltage△U:(10V~200V
Current△I:(1.5A~30A
Record Frequency
1Hz
Charge
Charge Mode
Constant Current ChargeConstant Voltage Charge
Constant Current and Constant Voltage Charge
End Conditon
Main channel: VoltageCurrentRelative TimeCapacity
Auxiliary channel: Temperature , Voltage
Discharge
Discharge Mode
Constant Current DischargeConstant Power Discharge
End Condition
Main channel: VoltageCurrentRelative TimeCapacity
Auxiliary channel: Temperature , Voltage
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop FunctionMax Support 3 Layers
Protection
Software Protection
l            Power-down Data Protection; NULL
l            Setting Protection ConditionSetting ParameterLow Voltage limitUpper Voltage limitLow Current limitUpper Current limitDelay Time
Characters of channel
4-wire connecting
Energy feedback
Discharge energy feed back to power grid
Mode of channel control
Control independently
Noise
<85dB
Data base
Use MySQL data base to manage testing data centralizely
Communication way of host computer
Based on TCP/IP protocol
Data Output
EXCELTXTGraph
Communication Interface
net port
Per Unit Main Channels No.
1
Temperature Auxiliary channel with each main channel
optional
Voltage Auxiliary channel with each main channel
optional
Dimensions
W*D*H1350*733*1800 (mm)

Equipment Working Environment
Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)
Equipment Picture


Picture for Reference Only, take the material object as the standard.