SPEC. of BTS-5V1mA battery testing system

Liu Fang | Shenzhen Neware | Office +86 755 83128709 | Mobile +86 13714507497 | Fax +86 755 83109966 | liufang@neware.com.cn  | http://www.neware.com.cn/  | Twitter @NewareApril    

BTS-5V3A Battery Testing Equipment

Equipment Model :BTS-5V3A Battery Testing Equipment      Equipment Item Code:CT-3008W-5V3A-S1

Project index
Parameter index
Input Power
AC 110V/220V ±10% 50Hz/60Hz
resolution
AD:16bit;DA:16bit
Input Resistance
≥1MΩ
Input Power
224W
Channel Features
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode
Channel Control Mode
Voltage
Per Channel Voltage Range
Charge:10mV~5V;Discharge:0.8V~5V
Accuracy
± 0.1% of range(Full-scale)
Stability
± 0.1% of range(Full-scale)
Current
Per Channel Current Range
Charge:6mA~3A;Discharge:6mA~3A
Accuracy
± 0.1% of range(Full-scale)
Stability
± 0.1% of range(Full-scale)
Power
Per Channel Output Power
15W
Stability
± 0.2% of range(Full-scale)
Time
Current Response Time
The Current gets to 3A Hardware Response Time is 20ms
Step Time Range
1min ≤Single Step Time Range≤365*24 h,
Time Form Support 00:00:00(h、min、s)
Data Recording
Record Condition
Time△t:(1s ~60000s)
Voltage△U:(10mV~5V)
Current△I:(6mA~3A)
Record Frequency
1Hz
Charge
Charge Mode
Constant Current Charge、Constant Voltage Charge、
Constant Current and Constant Voltage Charge
End Conditon
Voltage、Current、Relative Time、Capacity
Discharge
Discharge Mode
Constant Current Discharge、Constant Power Discharge
End Condition
Voltage、Current、Relative Time、Capacity
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
63
Nested Loop
Nested loop Function,Max Support 3 Layers
Protection
Software Protection
l            Power-down Data Protection; NULL
l            Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
Voltage and Current Testing Sample
4-wire connecting
Noise
<85dB
Communication way of host computer
RS232
Data Output
EXCEL、TXT、Graph
Communication Interface
Serial port
Per Unit Main Channels No.
8
Dimensions
3U (164),W*D*H:480*330*130 (mm)


Equipment Working Environment

Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)
Equipment Picture
Picture for Reference Only, take the material object as the standard.




标签: