Spec. of EVTS-500V300A EV/HEV/PHEV Test system
EVTS-500V300A    EV/HEV/PHEV Battery  Testing System 
Equipment Model :EVTS-500V300A  Battery Testing Equipment       Equipment Item Code:CE-6001W-500V300A 
Project index 
 | 
Parameter index 
 | |
Input Power 
 | 
AC 380V ±10% 50Hz 
 | |
resolution 
 | 
14bit 
 | |
Single-phase power 
 | 
65KW 
 | |
Single-phase current 
 | ||
Input Power 
 | 
195KW 
 | |
Voltage 
 | 
Per  
 | 
Charge:25V~500V;Discharge:25V~500V 
 | 
Accuracy 
 | 
± 1% of range(Full-scale) 
 | |
Stability 
 | 
± 1% of range(Full-scale) 
 | |
Current 
 | 
Per  
 | 
Charge: 
 | 
Accuracy 
 | 
± 1% of range(Full-scale) 
 | |
Stability 
 | 
± 15% of range(Full-scale) 
 | |
Power 
 | 
Per Channel Output Power  
 | 
150KW 
 | 
Stability 
 | 
± 2% of range(Full-scale) 
 | |
Time 
 | 
Current Response Time  
 | 
The Current gets to  
 | 
Single Step Time Range≤365*24 h, 
Time Form Support 00:00:00(h、min、s) 
 | ||
Auxiliary Channel 
 | 
Type of Auxiliary Channel 
 | 
Test&Control Temperature &Voltage of unit cell (max with 248 auxiliary channels) 
 | 
﹣ 
 | ||
Temperature Stability 
 | 
±(1% of reading +  
 | |
Temperature Resolution 
 | ||
10 mV~5V 
 | ||
Voltage Stability 
 | 
± 0.1% of full range 
 | |
Data Recording 
 | 
Record Condition 
 | 
Time△t:(1s ~60000s) 
 | 
Current△I:( 
 | ||
Record Frequency  
 | 
1Hz 
 | |
Charge 
 | 
Charge Mode  
 | 
Constant Current Charge、Constant Voltage Charge、 
Constant Current and Constant Voltage Charge 
 | 
End Conditon 
 | 
Main channel: Voltage、Current、Relative Time、Capacity 
Auxiliary channel: Temperature , Voltage 
 | |
Discharge 
 | 
Discharge Mode 
 | 
Constant Current Discharge、Constant Power Discharge 
 | 
End Condition 
 | 
Main channel: Voltage、Current、Relative Time、Capacity 
Auxiliary channel: Temperature , Voltage  
 | |
Cycle 
 | 
1~65535 times 
 | |
Max Steps Per  
 | 
254 
 | |
Nested  
 | 
Nested loop Function,Max Support 3 Layers 
 | |
Protection 
 | 
Software Protection 
 | 
l            Power-down Data Protection; NULL 
 | 
l            Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time 
 | ||
Characters of channel 
 | 
4-wire connecting 
 | |
Energy feedback 
 | 
Discharge energy feed back to power grid 
 | |
Mode of channel control 
 | 
Control independently 
 | |
Noise 
 | 
<85dB 
 | |
Data base 
 | 
Use MySQL data base to manage testing data centralizely 
 | |
Communication way of host computer 
 | 
Based on TCP/IP protocol 
 | |
Data Output  
 | 
EXCEL、TXT、Graph 
 | |
Communication Interface 
 | 
net port 
 | |
Per Unit  
 | 
1 
 | |
Temperature Auxiliary channel with each main channel 
 | 
optional 
 | |
Voltage Auxiliary channel with each main channel 
 | 
optional 
 | |
Dimensions 
 | 
W*D*H:1350*733*1800 (mm) 
 | |
Equipment Working Environment 
Project index 
 | 
Parameter index 
 | 
≤ 70% RH ( no coagulation of vapor) 
 | |
≤ 80% RH ( no coagulation of vapor) 
 | |
Picture for Reference Only, take the material object as the standard. 
 | 