2012年2月10日星期五

Spec. of EVTS-500V300A EV/HEV/PHEV Test system

EVTS-500V300A   EV/HEV/PHEV Battery Testing System

Equipment Model EVTS-500V300A Battery Testing Equipment       Equipment Item CodeCE-6001W-500V300A

Project index
Parameter index
Input Power
AC 380V ±10% 50Hz
resolution
14bit
Single-phase power
65KW
Single-phase current
296A
Input Power
195KW
Voltage
Per Channel Voltage Range
Charge25V~500VDischarge25V~500V
Accuracy
± 1% of rangeFull-scale
Stability
± 1% of rangeFull-scale
Current
Per Channel Current Range
Charge15A~300ADischarge15A~300A
Accuracy
± 1% of rangeFull-scale
Stability
± 15% of rangeFull-scale
Power
Per Channel Output Power
150KW
Stability
± 2% of rangeFull-scale
Time
Current Response Time
The Current gets to 300A Hardware Response Time is 1s
Step Time Range
Single Step Time Range≤365*24 h
Time Form Support 000000(hmins)
Auxiliary Channel
Type of Auxiliary Channel
Test&Control Temperature &Voltage of unit cell (max with 248 auxiliary channels)
Temperature Range
25~110
Temperature Stability
±1% of reading + 1
Temperature Resolution
0.1
Voltage Range
10 mV~5V
Voltage Stability
± 0.1% of full range
Data Recording
Record Condition
Time△t:(1s ~60000s
Voltage△U:(25V~500V
Current△I:(15A~300A
Record Frequency
1Hz
Charge
Charge Mode
Constant Current ChargeConstant Voltage Charge
Constant Current and Constant Voltage Charge
End Conditon
Main channel: VoltageCurrentRelative TimeCapacity
Auxiliary channel: Temperature , Voltage
Discharge
Discharge Mode
Constant Current DischargeConstant Power Discharge
End Condition
Main channel: VoltageCurrentRelative TimeCapacity
Auxiliary channel: Temperature , Voltage
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop FunctionMax Support 3 Layers
Protection
Software Protection
l            Power-down Data Protection; NULL
l            Setting Protection ConditionSetting ParameterLow Voltage limitUpper Voltage limitLow Current limitUpper Current limitDelay Time
Characters of channel
4-wire connecting
Energy feedback
Discharge energy feed back to power grid
Mode of channel control
Control independently
Noise
<85dB
Data base
Use MySQL data base to manage testing data centralizely
Communication way of host computer
Based on TCP/IP protocol
Data Output
EXCELTXTGraph
Communication Interface
net port
Per Unit Main Channels No.
1
Temperature Auxiliary channel with each main channel
optional
Voltage Auxiliary channel with each main channel
optional
Dimensions
W*D*H1350*733*1800 (mm)


Equipment Working Environment

Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)

Picture for Reference Only, take the material object as the standard.



Spec. of BTS-5V5mA Battery Tester

BTS-5V5mA Battery Testing Equipment

Equipment Model BTS-5V5mA Battery Testing Equipment   Equipment Item Code:CT-3008W-5V5mA-S1

Project index
Parameter index
Input Power
AC 110V/220V ±10% 50Hz/60Hz
Resolution
AD16bitDA12bit
Input Resistance
1MΩ
Input Power
373mW
Channel Features
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode
Independent Control
Voltage
Per Channel Voltage Range
Charge10mV~5VDischarge10mV~5V
Accuracy
± 0.1% of rangeFull-scale
Stability
± 0.1% of rangeFull-scale
Current
Per Channel Current Range
Charge0.01mA~5mADischarge0.01mA~5mA
Accuracy
± 0.1% of rangeFull-scale
Stability
± 0.1% of rangeFull-scale
Power
Per Channel Output Power
25mW
Stability
± 0.2% of  FS
Time
Current Response Time
The Current gets to 5mA Hardware Response Time is 20ms
Step Time Range
1min ≤Single Step Time Range≤365*24 h
Time Form Support 000000(hmins)
Data Recording
Record Condition
Time△t:(1s ~60000s
Voltage△U:(10mV~5V
Current△I:(0.01mA~5mA
Record Frequency
1Hz
Charge
Charge Mode
Constant Current ChargeConstant Voltage Charge
Constant Current and Constant Voltage Charge
End Conditon
VoltageCurrentRelative TimeCapacity
Discharge
Discharge Mode
Constant Current DischargeConstant Power Discharge
End Condition
VoltageCurrentRelative TimeCapacity
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
63
Nested Loop
Nested loop FunctionMax Support 3 Layers
Protection
Software Protection
l            Power-down Data Protection; NULL
l            Setting Protection ConditionSetting ParameterLow Voltage limitUpper Voltage limitLow Current limitUpper Current limitDelay Time
Voltage and Current Testing Sample
4-wire connecting
Noise
<85dB
Communication way of Host computer
RS232
Data Output
EXCELTXTGraph
Communication Interface
Serial port (RS232)
Per Unit Main Channels No.
8
Dimensions
3U (164)W*D*H480*330*130 (mm)


Equipment Working Environment

Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)
Equipment Picture

Picture for Reference Only, take the material object as the standard.



| Shenzhen Neware | Office +86 755 83108866 | Mobile +86 13714507497 | Fax +86 755 83109966 | liufang@neware.com.cn | http://www.newaretechnology.com/ | Twitter @NewareApril