2012年2月10日星期五

Spec. of EVTS-500V300A EV/HEV/PHEV Test system

EVTS-500V300A   EV/HEV/PHEV Battery Testing System

Equipment Model EVTS-500V300A Battery Testing Equipment       Equipment Item CodeCE-6001W-500V300A

Project index
Parameter index
Input Power
AC 380V ±10% 50Hz
resolution
14bit
Single-phase power
65KW
Single-phase current
296A
Input Power
195KW
Voltage
Per Channel Voltage Range
Charge25V~500VDischarge25V~500V
Accuracy
± 1% of rangeFull-scale
Stability
± 1% of rangeFull-scale
Current
Per Channel Current Range
Charge15A~300ADischarge15A~300A
Accuracy
± 1% of rangeFull-scale
Stability
± 15% of rangeFull-scale
Power
Per Channel Output Power
150KW
Stability
± 2% of rangeFull-scale
Time
Current Response Time
The Current gets to 300A Hardware Response Time is 1s
Step Time Range
Single Step Time Range≤365*24 h
Time Form Support 000000(hmins)
Auxiliary Channel
Type of Auxiliary Channel
Test&Control Temperature &Voltage of unit cell (max with 248 auxiliary channels)
Temperature Range
25~110
Temperature Stability
±1% of reading + 1
Temperature Resolution
0.1
Voltage Range
10 mV~5V
Voltage Stability
± 0.1% of full range
Data Recording
Record Condition
Time△t:(1s ~60000s
Voltage△U:(25V~500V
Current△I:(15A~300A
Record Frequency
1Hz
Charge
Charge Mode
Constant Current ChargeConstant Voltage Charge
Constant Current and Constant Voltage Charge
End Conditon
Main channel: VoltageCurrentRelative TimeCapacity
Auxiliary channel: Temperature , Voltage
Discharge
Discharge Mode
Constant Current DischargeConstant Power Discharge
End Condition
Main channel: VoltageCurrentRelative TimeCapacity
Auxiliary channel: Temperature , Voltage
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop FunctionMax Support 3 Layers
Protection
Software Protection
l            Power-down Data Protection; NULL
l            Setting Protection ConditionSetting ParameterLow Voltage limitUpper Voltage limitLow Current limitUpper Current limitDelay Time
Characters of channel
4-wire connecting
Energy feedback
Discharge energy feed back to power grid
Mode of channel control
Control independently
Noise
<85dB
Data base
Use MySQL data base to manage testing data centralizely
Communication way of host computer
Based on TCP/IP protocol
Data Output
EXCELTXTGraph
Communication Interface
net port
Per Unit Main Channels No.
1
Temperature Auxiliary channel with each main channel
optional
Voltage Auxiliary channel with each main channel
optional
Dimensions
W*D*H1350*733*1800 (mm)


Equipment Working Environment

Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)

Picture for Reference Only, take the material object as the standard.



0 条评论:

发表评论

订阅 博文评论 [Atom]

<< 主页