BTS-5V20mA Battey Testing Equipment
Equipment model: BTS-5V20mA battery testing equipment
Equipment item code: CT-3008W-5V20mA-S4

Project index
Parameter index
Input Power
AC 110V/220V±10% 50Hz/60Hz
resolution
AD16bitDA12bit
Input Resistance
1MΩ
Input Power
1493mW
Channel Features
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode
Independent Control
Voltage
Per Channel Voltage Range
Charge10mV~5VDischarge10mV~5V
Accuracy
± 0.1% of rangeFull-scale
Stability
± 0.1% of rangeFull-scale
Current
Per Channel Current Range
Charge0.04mA~20mADischarge0.04mA~20mA
Accuracy
± 0.1% of rangeFull-scale
Stability
± 0.1% of rangeFull-scale
Power
Per Channel Output Power
100mW
Stability
± 0.2% of rangeFull-scale
Time
Current Response Time
The Current gets to 20mA Hardware Response Time is 20ms
Step Time Range
1min ≤Single Step Time Range≤365*24 h
Time Form Support 000000(hmins)
Data Recording
Record Condition
Time△t:(1s ~60000s
Voltage△U:(10mV~5V
Current△I:(0.04mA~20mA
Record Frequency
1Hz
Charge
Charge Mode
Constant Current ChargeConstant Voltage Charge
Constant Current and Constant Voltage Charge
End Conditon
VoltageCurrentRelative TimeCapacity
Discharge
Discharge Mode
Constant Current DischargeConstant Power Discharge
End Condition
VoltageCurrentRelative TimeCapacity
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
63
Nested Loop
Nested loop FunctionMax Support 3 Layers
Protection
Software Protection
l  Power-down Data Protection; NULL
l  Setting Protection ConditionSetting ParameterLow Voltage limitUpper Voltage limitLow Current limitUpper Current limitDelay Time
Voltage and Current Testing Sample
4-wire connecting
Noise
<80dB
Communication way of host computer
RS232
Data Output
EXCELTXTGraph
Communication Interface
Serial  Port (RS232)
Per Unit Main Channels No.
8
Dimensions
3U (164)W*D*H480*330*130 (mm)
Equipment Working Environment

Project index
Parameter index
Working Temperature Range
0℃~40℃
Storage Temperature Range
-10℃~50℃
Working Environment Relative Humidity Range
≤ 70% RH ( no coagulation of vapor)
Storage Environment Relative Humidity Range
≤ 80% RH ( no coagulation of vapor)

 

 